Analytic Wavelet-Based Ultrasonic Pulse Differentiation for Injection Mold Cavity Pressure Measurement
Oleh:
Theurer, Charles B.
;
Gao, Robert X.
;
Kazmer, David O.
;
Li, Zhang
Jenis:
Article from Journal - ilmiah internasional
Dalam koleksi:
Journal of Manufacturing Science and Engineering vol. 128 no. 1 (Feb. 2006)
,
page 370-377.
Topik:
cavity flows
;
analytic
;
wavelet - based
;
ultrasonic
;
injection mold
;
cavity
;
pressure measurement
Ketersediaan
Perpustakaan Pusat (Semanggi)
Nomor Panggil:
JJ93.8
Non-tandon:
1 (dapat dipinjam: 0)
Tandon:
tidak ada
Lihat Detail Induk
Isi artikel
A new signal - processing technique based on analytic wavelet transform has been develop ed for detecting and differentiating temporally overlapped ultrasonic pulse trains that carry spatially distributed pressure information across an injection mold cavity. Compared to conventional wavelets that have a constant relative bandwidth at all the scales, the analytic wavelets investigated in this paper feature variable relative bandwidth, making it possible to simultaneously match the frequency characteristics of the ultrasonic pulse trains transmitted from the mold - embedded pressure sensors. As a result, more accurate detection and differentiation of the temporal and spectral information embedded within the ultrasonic pulse trains could be achieved. Theoretical framework for the analytic wavelet transform was established, and a multichannel ultrasonic pulse detector based on the complex Morlet wavelet was designed and experimentally investigated. The results have confirmed the effectiveness of the new signal - processing technique for on - line pressure sensing for injection molding process monitoring.
Opini Anda
Klik untuk menuliskan opini Anda tentang koleksi ini!
Kembali
Process time: 0 second(s)