Anda belum login :: 26 Apr 2025 18:46 WIB
Home
|
Logon
Hidden
»
Administration
»
Collection Detail
Detail
Local Pool Boiling Coefficients on The Outside Surface of A Horizontal Tube
Oleh:
Kang, Myeong-Gie
Jenis:
Article from Bulletin/Magazine
Dalam koleksi:
Journal of Heat Transfer vol. 127 no. 8 (Aug. 2005)
,
page 949-953.
Topik:
pool boiling
;
pool boiling
;
surface
;
horizontal tube
Ketersediaan
Perpustakaan Pusat (Semanggi)
Nomor Panggil:
JJ90.9
Non-tandon:
1 (dapat dipinjam: 0)
Tandon:
tidak ada
Lihat Detail Induk
Isi artikel
Changes in local pool boiling heat transfer coefficients on the outside surface of a 51 mm dia horizontal tube have been investigated experimentally in water at atmospheric pressure. The local values were determined at every 45 deg from the very bottom to the uppermost of the tube periphery, and a representative value was suggested. The maximum and the minimum local coefficients were observed at the azimuthal angles of 45 and 180 deg, respectively, from the tube bottom. The coefficient at 90 deg can be suggested as the representative of the coefficients. The major mechanisms affecting heat transfer on the surface were liquid agitation and bubble coalescence. Moreover, it is identified that the data can be curve fitted as h(b) = C1 + C2 q(n).
Opini Anda
Klik untuk menuliskan opini Anda tentang koleksi ini!
Kembali
Process time: 0 second(s)