ArtikelExperimental Investigation of Natural Convection in An Asymmetrically Heated Vertical Channel with An Asymmetric Chimney  
Oleh: Manca, Oronzio ; Musto, Marilena ; Naso, Vincenzo
Jenis: Article from Bulletin/Magazine
Dalam koleksi: Journal of Heat Transfer vol. 127 no. 8 (Aug. 2005), page 888-896.
Topik: natural convection; investigation; natural convection; heated vertical channel; asymmetric chimney
Ketersediaan
  • Perpustakaan Pusat (Semanggi)
    • Nomor Panggil: JJ90.9
    • Non-tandon: 1 (dapat dipinjam: 0)
    • Tandon: tidak ada
    Lihat Detail Induk
Isi artikelAn experimental investigation on air natural convection, in a vertical channel asymmetrically heated at uniform heat flux, with downstream unheated parallel extensions, is carried out. One extension is coplanar to the unheated channel wall and the distance between the extensions is equal to or greater than the channel gap (geometrically asymmetric chimney). Experiments are performed with different values of the wall heat flux, aspect ratio (L(h) / b), extension ratio (L / L(h)) and expansion ratio (B / b). For the largest value of the aspect ratio (L(h) / b = 10), the adiabatic extensions improve the thermal performance in terms of lower maximum wall temperature of the channel. Optimal configurations of the system with asymmetrical chimney are detected. Flow visualization shows a cold inflow in the channel - chimney system that penetrates down below the channel exit section. Maximum wall temperatures and channel Nusselt numbers are correlated to the channel Rayleigh number, Ra*, and to the geometrical parameters, in the ranges 3.0 × 10(2) <= Ra*B / b <= 1.010(5), 1.0 B / b <= 3.0 and 1.0 <= L / Lh <= 4.0 with L(h) / b = 5.0 and 10.0.
Opini AndaKlik untuk menuliskan opini Anda tentang koleksi ini!

Kembali
design
 
Process time: 0 second(s)