Anda belum login :: 25 Apr 2025 00:17 WIB
Home
|
Logon
Hidden
»
Administration
»
Collection Detail
Detail
Perbandingan Nilai Diagnostik IgE Spesifik Tungau Debu Rumah, Metode Elisa dan Imunoblot pada Rinitis Alergi
Oleh:
Habsari, Janti Tri
;
Aryati
;
Pawarti, Dwi Reno
Jenis:
Article from Journal - ilmiah nasional - terakreditasi DIKTI
Dalam koleksi:
Indonesian Journal of Clinical Pathology and Medical Laboratory vol. 22 no. 02 (Mar. 2016)
,
page 119-126.
Topik:
Allergic Rhinitis
;
Specific IgE Due to HDM
;
Diagnostic Value
;
ELISA
;
Immunoblot
;
Rinitis Alergi
;
IgE Spesifik TDR
;
Nilai Diagnostik
Fulltext:
I01 v22 n2 p119 kelik2017.pdf
(157.42KB)
Ketersediaan
Perpustakaan FK
Nomor Panggil:
I01.K
Non-tandon:
1 (dapat dipinjam: 0)
Tandon:
tidak ada
Lihat Detail Induk
Isi artikel
The detection of allergen types is very helpful in allergic rhinitis (AR) management. Some methods had been performed to examine the specific IgE due to HDM such as ELISA and immunoblot methods. The aim of this research is to know the difference of specific IgE diagnostic value due to HDM between ELISA and immunoblot in allergic rhinitis method which is expected to be used as in vitro alternative method which is safe, fast, effective, with a high sensitivity and specificity by provement. The samples were allergic rhinitis and non-allergic rhinitis patients at ENT of Head and Neck Out patients Clinic of Dr. Soetomo Hospital Surabaya. The sera was examined for specific IgE due to HDM by ELISA and immunoblot methods and then analyzed for its diagnostic value using the 2 x 2 table with a 95% confidence interval. The comparation between both methods were analyzed with Wilcoxon test. The diagnostic value of the specific HDM IgE with immunoblot method showed sensitivity of 90% and 80% specificity, positive predictive value 90% and the negative 80% and diagnostic efficiency 86.67%. The positive likelihood ratio 4.5 and the negative one 0.125. The diagnostic value of the specific IgE HDM/D.p with ELISA showed a sensitivity of 75% and specificity 75%, the positive predictive value 85.71% and the negative one 0% and diagnostic efficiency 75%. The positive likelihood ratio was 3 and the negative one 0.33. The diagnostic value of the specific IgE HDM with immunoblot showed a sensitivity of 90% and specificity 80%, the positive predictive value 90% and the negative one 80% and the diagnostic efficiency 86.67%. The positive likelihood ratio was 4.5 and the negative one 0.125. The difference of diagnostic value in both methods revealed that the p value was 0.013. It can be concluded in this study that there was a significant difference of specific IgE due to HDM between ELISA and immunoblot methods in allergic rhinitis.
Opini Anda
Klik untuk menuliskan opini Anda tentang koleksi ini!
Kembali
Process time: 0 second(s)