Anda belum login :: 18 Apr 2025 18:23 WIB
Detail
ArtikelShort-Wavelength Automated Perimetry Parameters at Baseline and Following Remission in Patients With Birdshot Retinochoroidopathy  
Oleh: Maleki, Arash ; Swan, Robert T. ; Silpa-Archa, Sukhum ; Preble, Janine M. ; Yuchen He ; Foster, C. Stephen
Jenis: Article from Journal - ilmiah internasional
Dalam koleksi: American Journal of Ophthalmology (keterangan: ada di ClinicalKey) vol. 163 (Mar. 2016), page 83–92.
Topik: Birdshot Retinochoroidopathy
Fulltext: A12 v163 p83 kelik2016.pdf (2.35MB)
Ketersediaan
  • Perpustakaan FK
    • Nomor Panggil: A12.K
    • Non-tandon: 1 (dapat dipinjam: 0)
    • Tandon: tidak ada
    Lihat Detail Induk
Isi artikelPurpose: To identify changes in short-wavelength automated perimetry patterns and parameters between the active and inactive states. Design: Retrospective cohort study with age-matched, normal controls. Methods: SETTING: Private tertiary referral center. STUDY POPULATION: Seventy-five eyes of 38 patients with active birdshot retinochoroidopathy and 37 eyes of 37 historical normal controls. INTERVENTION: Thirty-seven patients received immunomodulatory therapy. A fluocinolone acetonide intravitreal implant (Retisert) was implanted in both eyes of 1 patient as an initial treatment. MAIN OUTCOME MEASURES: Changes in short-wavelength automated perimetry total deviation scores, pattern deviation scores, mean deviation, and pattern standard deviation in the active phase and the remission state. Results: Mean deviation (P = .006), pattern standard deviation (P = .001), total deviation score (P = .002), and pattern deviation score (P = .007) were significantly different from the active phase to the remission state. The length of time required to achieve remission did not significantly affect the changes in mean deviation (regression coefficient = 0.01; P = .92), pattern standard deviation (regression coefficient = 0.01; P = .87), total deviation score (regression coefficient = -0.1; P = .32), or pattern deviation score (regression coefficient = 0.1; P = .36) from the active phase to the remission state. Conclusion: There was significant improvement in total deviation score, pattern deviation score, mean deviation, and pattern standard deviation on short-wavelength automated perimetry as patients achieved remission. Short-wavelength automated perimetry appears to be a useful and complementary modality in monitoring disease activity in birdshot retinochoroidopathy.
Opini AndaKlik untuk menuliskan opini Anda tentang koleksi ini!

Kembali
design
 
Process time: 0.015625 second(s)