Anda belum login :: 18 Apr 2025 18:23 WIB
Home
|
Logon
Hidden
»
Administration
»
Collection Detail
Detail
Short-Wavelength Automated Perimetry Parameters at Baseline and Following Remission in Patients With Birdshot Retinochoroidopathy
Oleh:
Maleki, Arash
;
Swan, Robert T.
;
Silpa-Archa, Sukhum
;
Preble, Janine M.
;
Yuchen He
;
Foster, C. Stephen
Jenis:
Article from Journal - ilmiah internasional
Dalam koleksi:
American Journal of Ophthalmology (keterangan: ada di ClinicalKey) vol. 163 (Mar. 2016)
,
page 83–92.
Topik:
Birdshot Retinochoroidopathy
Fulltext:
A12 v163 p83 kelik2016.pdf
(2.35MB)
Ketersediaan
Perpustakaan FK
Nomor Panggil:
A12.K
Non-tandon:
1 (dapat dipinjam: 0)
Tandon:
tidak ada
Lihat Detail Induk
Isi artikel
Purpose: To identify changes in short-wavelength automated perimetry patterns and parameters between the active and inactive states. Design: Retrospective cohort study with age-matched, normal controls. Methods: SETTING: Private tertiary referral center. STUDY POPULATION: Seventy-five eyes of 38 patients with active birdshot retinochoroidopathy and 37 eyes of 37 historical normal controls. INTERVENTION: Thirty-seven patients received immunomodulatory therapy. A fluocinolone acetonide intravitreal implant (Retisert) was implanted in both eyes of 1 patient as an initial treatment. MAIN OUTCOME MEASURES: Changes in short-wavelength automated perimetry total deviation scores, pattern deviation scores, mean deviation, and pattern standard deviation in the active phase and the remission state. Results: Mean deviation (P = .006), pattern standard deviation (P = .001), total deviation score (P = .002), and pattern deviation score (P = .007) were significantly different from the active phase to the remission state. The length of time required to achieve remission did not significantly affect the changes in mean deviation (regression coefficient = 0.01; P = .92), pattern standard deviation (regression coefficient = 0.01; P = .87), total deviation score (regression coefficient = -0.1; P = .32), or pattern deviation score (regression coefficient = 0.1; P = .36) from the active phase to the remission state. Conclusion: There was significant improvement in total deviation score, pattern deviation score, mean deviation, and pattern standard deviation on short-wavelength automated perimetry as patients achieved remission. Short-wavelength automated perimetry appears to be a useful and complementary modality in monitoring disease activity in birdshot retinochoroidopathy.
Opini Anda
Klik untuk menuliskan opini Anda tentang koleksi ini!
Kembali
Process time: 0.015625 second(s)