Determining the Air Gap Length of an Axial Flux Wound Rotor Synchronous Generator
Oleh:
Multi, Abdul
;
Garniwa, Iwa
;
Sudibyo, Uno Bintang
Jenis:
Article from Journal - ilmiah nasional - terakreditasi DIKTI
Dalam koleksi:
Makara Journal of Technology vol. 17 no. 2 (Aug. 2013)
,
page 87-93.
Topik:
Synchronous Generator
;
Axial Flux
;
Wound Rotor
;
Air Gap
;
Efficiency
Fulltext:
269-299-1-PB.pdf
(260.75KB)
Ketersediaan
Perpustakaan Pusat (Semanggi)
Nomor Panggil:
MM64
Non-tandon:
1 (dapat dipinjam: 0)
Tandon:
tidak ada
Lihat Detail Induk
Isi artikel
The air gap length of the designed axial flux wound rotor (AFWR) synchronous generator is determined properly according to the design parameters. One of the distinct advantages of an axial flux (AF) machine is its adjustable air gap. An AF generator’s performance might be controlled by adjusting its air gap. The designed generator has a small-scale capacity that has 1 kW, 380 V, and 50 Hz. The windings are laid into slots made from laminated core. The slots are carved in the face of the stator and rotors. The generator has a single-double-sided slotted wound stator sandwiched between twin rotors. The effect of air gap changes on its performance can be seen from the calculation results using the given equations. The results reveal electric quantities suited to the machine’s effective performance. The smaller the air gap, the greater the efficiency and power factor and the smaller the armature current and voltage. The efficiency and armature current for 0.1 cm air gap are 85.30 % and 1.815 A, respectively.
Opini Anda
Klik untuk menuliskan opini Anda tentang koleksi ini!
Kembali
Process time: 0.015625 second(s)