Treatment of Symptomatic Intracranial Atherosclerotic Stenosis with a Normal-sized Gateway™ Balloon and Wingspan™ Stent
Oleh:
Yu, J.
;
Wang, L.
;
Deng, J.P.
;
Li, J.
Jenis:
Article from Journal - ilmiah internasional
Dalam koleksi:
The Journal of International Medical Research vol. 38 no. 06 (Nov. 2010)
,
page 1968-1974.
Topik:
Gateway Trade
;
Balloon Catheter
;
Wingspan Trade
;
Stent
;
Angioplasty
;
Intracranial Atherosclerotic Stenosis
;
Stroke
;
Safety
;
Performance
Fulltext:
s10.pdf
(119.33KB)
Ketersediaan
Perpustakaan FK
Nomor Panggil:
J11.K
Non-tandon:
1 (dapat dipinjam: 0)
Tandon:
tidak ada
Lihat Detail Induk
Isi artikel
The safety and performance of angioplasty using a normal-sized Gateway™ balloon and Wingspan™ stent for intracranial atherosclerotic stenosis were assessed. Seventy-two patients with intracranial stenosis (= 50%) were treated using an undersized (group U) or normal-sized (group N) Gateway™ balloon and a Wingspan™ stent. All patients were successfully stented. Stenosis improved from 74.2% before treatment to 23.8% immediately after treatment in group U and from 70.9% to 20.1% in group N. The two groups had similar rates of major periprocedural neurological complications (9.0% overall), none of which led to death. Residual stenosis at follow-up was 40.8% and 32.5% in groups U and N, respectively. In-stent re-stenosis (ISR) was significantly less frequent in group N (22.0%) than in group U (33.3%). It is concluded that use of a normal-sized Gateway™ balloon and Wingspan™ stent appears to be safe, to have a high rate of technical success, good immediate post-operative results and a low ISR rate.
Opini Anda
Klik untuk menuliskan opini Anda tentang koleksi ini!
Kembali
Process time: 0 second(s)