Anda belum login :: 16 Apr 2025 19:56 WIB
Home
|
Logon
Hidden
»
Administration
»
Collection Detail
Detail
Plasma concentration of 3-hydroxyisovaleryl carnitine is an early and sensitive indicator of marginal biotin deficiency in humans
Oleh:
Stratton, Shawna L.
;
Horvath, Thomas D.
;
Bogusiewicz, Anna
;
Matthews, Nell I.
;
Henrich, Cindy L.
;
Spencer, Horace J.
;
Moran, Jeffery H.
;
Mock, Donald M.
Jenis:
Article from Journal - ilmiah internasional
Dalam koleksi:
The American Journal of Clinical Nutrition vol. 92 no. 06 (Dec. 2010)
,
page 1399-1405.
Topik:
Marginal Biotin Deficiency
Fulltext:
Am J Clin Nutr-2010-Stratton-1399-405.pdf
(370.74KB)
Ketersediaan
Perpustakaan FK
Nomor Panggil:
A07.K.2010.02
Non-tandon:
1 (dapat dipinjam: 0)
Tandon:
tidak ada
Lihat Detail Induk
Isi artikel
Background: Blood-based indicators of biotin status in humans were shown to be useful tools in several clinical situations, including pregnancy. We previously validated the activity of the biotin-dependent enzyme propionyl-coenzyme A carboxylase (PCC) in lymphocytes as a sensitive and specific blood-based indicator of marginal degrees of biotin deficiency. However, the measurement of PCC activity in population studies presents substantial analytic challenges. 3-Hydroxyisovaleryl carnitine (3HIA-carnitine) increases in response to the decreased activity of the biotin-dependent enzyme methylcrotonyl-coenzyme A carboxylase and might reflect biotin status. Objective: We sought to determine whether the plasma concentration of 3HIA-carnitine increases significantly in marginal biotin deficiency. Design: We experimentally induced marginal, asymptomatic biotin deficiency in 10 healthy adults (8 women) by having the subjects consume undenatured egg white for 28 d; biotin status was then repleted. Plasma concentrations of 3HIA-carnitine were measured on days 0, 14, 28, 35, and 50 by liquid chromatography–mass spectroscopy. Results: The mean plasma 3HIA-carnitine concentration increased with depletion (P < 0.0001) and decreased with repletion (P < 0.0001). Plasma 3HIA-carnitine concentrations were greater than the upper limit of normal concentrations in 7 of 10 subjects by day 14 and in 9 of 10 subjects by day 28 and decreased to within normal limits in 9 of 10 subjects by day 50. Conclusions: These studies provide evidence that 3HIA-carnitine is an early and sensitive indicator of marginal biotin deficiency. The ease of sample collection, small sample volume requirement, and stability of 3HIA-carnitine during storage suggest that plasma 3HIA-carnitine concentration is likely to be a useful indicator of marginal biotin deficiency for larger population studies.
Opini Anda
Klik untuk menuliskan opini Anda tentang koleksi ini!
Kembali
Process time: 0 second(s)