ArtikelHeat Transfer Coefficients and Film-Cooling Effectiveness on A Gas Turbine Blade Tip  
Oleh: Han, Je-Chin ; Jae, Su Kwak
Jenis: Article from Bulletin/Magazine
Dalam koleksi: Journal of Heat Transfer vol. 125 no. 3 (Jun. 2003), page 494-502.
Topik: GAS - TURBINES; heat transfer; coefficients; film - cooling; gas turbine; blade tip
Ketersediaan
  • Perpustakaan Pusat (Semanggi)
    • Nomor Panggil: JJ90.6
    • Non-tandon: 1 (dapat dipinjam: 0)
    • Tandon: tidak ada
    Lihat Detail Induk
Isi artikelThe detailed distributions of heat transfer coefficient and film cooling effectiveness on a gas turbine blade tip were measured using a hue detection based transient liquid crystals technique. Tests were performed on a five - bladed linear cascade with blow - down facility. The Reynolds number based on cascade exit velocity and axial chord length was 1.1 × 10(6) and the total turning angle of the blade was 97.7°. The overall pressure ratio was 1.2 and the inlet and exit Mach numbers were 0.25 and 0.59, respectively. The turbulence intensity level at the cascade inlet was 9.7 %. The blade model was equipped with a single row of film cooling holes at both the tip portion along the camber line and near the tip region of the pressure side. All measurements were made at the three different tip gap clearances of 1.0%, 1.5 %, and 2.5 % of blade span and the three blowing ratios of 0.5, 1, and 2. Results showed that, in general, heat transfer coefficient and film effectiveness increased with increasing tip gap clearance. As blowing ratio increased, heat transfer coefficient decreased, while film effectiveness increased. Results also showed that adding pressure side coolant injection would further decrease the blade tip heat transfer coefficient but increase film - cooling effectiveness.
Opini AndaKlik untuk menuliskan opini Anda tentang koleksi ini!

Kembali
design
 
Process time: 0 second(s)