ArtikelReattachment of Three-Dimensional Flow Adjacent to Backward-Facing Step  
Oleh: Nie, J. H. ; Armaly, B. F.
Jenis: Article from Bulletin/Magazine
Dalam koleksi: Journal of Heat Transfer vol. 125 no. 3 (Jun. 2003), page 422-428.
Topik: backward-facing step; reaatchment; three - dimensional flow; adjacent; backward - facing step
Ketersediaan
  • Perpustakaan Pusat (Semanggi)
    • Nomor Panggil: JJ90.6
    • Non-tandon: 1 (dapat dipinjam: 0)
    • Tandon: tidak ada
    Lihat Detail Induk
Isi artikelNumerical simulations for incompressible three - dimensional laminar forced convection flow adjacent to backward - facing step in rectangular duct are performed to examine the reattachment region of the separated flow on the stepped wall. The feasibility of utilizing the two - dimensional flow definition and the limiting streamline definition for identifying the reattachment line / region was examined. The downwash and the "jet - like" flow that develops near the sidewall creates significant spanwise flow adjacent to the stepped wall, making it difficult to identify a reattachment line / region both numerically and experimentally. The use of the line / region that identifies the location on a plane adjacent to the stepped wall where the gradient of the mean streamwise velocity component is zero (du / dy |y = 0 = 0) is recommended for code and apparatus validation of three-dimensional separated flow.