Anda belum login :: 22 Jul 2025 01:07 WIB
Detail
ArtikelPerfusion MRI (Tmax and MTT) correlation with xenon CT cerebral blood flow in stroke patients  
Oleh: Olivot, J-M ; Mlynash, M. ; Zaharchuk, G. ; Straka, M. ; Bammer, R.
Jenis: Article from Journal - ilmiah internasional
Dalam koleksi: Neurology (Official Journal of The American Academy of Neurology) vol. 72 no. 13 (Mar. 2009), page 1140-1145.
Topik: ACUTE ISCHEMIC STROKE; SYSTOLIC BLOOD PRESSURE
Ketersediaan
  • Perpustakaan FK
    • Nomor Panggil: N11.K.2009.03
    • Non-tandon: 1 (dapat dipinjam: 0)
    • Tandon: tidak ada
    Lihat Detail Induk
Isi artikelBackground: While stable xenon CT (Xe-CT) cerebral blood flow (CBF) is an accepted standard for quantitative assessment of cerebral hemodynamics, the accuracy of magnetic resonance perfusion-weighted imaging (PWI-MRI) is unclear. The Improved PWI Methodology in Acute Clinical Stroke Study compares PWI findings with Xe-CT CBF values in patients experiencing symptomatic severe cerebral hypoperfusion. Methods: We compared mean transit time (MTT) and Tmax PWI-MRI with the corresponding Xe-CT CBF values in 25 coregistered regions of interest (ROIs) of multiple sizes and locations in nine subacute stroke patients. Comparisons were performed with Pearson correlation coefficients (R). We performed receiver operating characteristic (ROC) curve analyses to define the threshold of Tmax and absolute MTT that could best predict a Xe-CT CBF <20 mL/100 g/minute. Results: The subjects’ mean (SD) age was 50 (15) years, the median (interquartile range [IQR]) NIH Stroke Scale score was 2 (2–6), and the median (IQR) time between MRI and Xe-CT was 12 (–7–19) hours. The total number of ROIs was 225, and the median (IQR) ROI size was 550 (360–960) pixels. Tmax correlation with Xe-CT CBF (R = 0.63, p < 0.001) was stronger than absolute MTT (R = 0.55, p < 0.001), p = 0.049. ROC curve analysis found that Tmax >4 seconds had 68% sensitivity, 80% specificity, and 77% accuracy and MTT >10 seconds had 68% sensitivity, 77% specificity, and 75% accuracy for predicting ROIs with Xe-CT CBF <20 mL/100 g/minute. Conclusion: Our results suggest that in subacute ischemic stroke patients, Tmax correlates better than absolute mean transit time (MTT) with xenon CT cerebral blood flow (Xe-CT CBF) and that both Tmax >4 seconds and MTT >10 seconds are strongly associated with Xe-CT CBF <20 mL/100 g/minute.
Opini AndaKlik untuk menuliskan opini Anda tentang koleksi ini!

Kembali
design
 
Process time: 0 second(s)