Anda belum login :: 18 Apr 2025 06:25 WIB
Detail
ArtikelThe causes of misdiagnosis and adverse outcomes in PGD  
Oleh: Wilton, L. ; Thornhill, A. ; Traeger-Synodinos, J. ; Sermon, K.D. ; Harper, J.C.
Jenis: Article from Journal - ilmiah internasional
Dalam koleksi: Human Reproduction vol. 24 no. 05 (May 2009), page 1221.
Topik: PGD/preimplantation genetic screening/misdiagnosis/contamination/allele dropout
Ketersediaan
  • Perpustakaan FK
    • Nomor Panggil: H07.K.2009.02
    • Non-tandon: 1 (dapat dipinjam: 0)
    • Tandon: tidak ada
    Lihat Detail Induk
Isi artikelThe European Society of Human Reproduction and Embryology PGD Consortium has collected data on PGD cycles and deliveries since 1997. From 15 158 cycles, 24 misdiagnoses and adverse outcomes have been reported; 12/2538 cycles after polymerase chain reaction and 12/12 620 cycles after fluorescence in situ hybridization. The causes of misdiagnosis include confusion of embryo and cell number, transfer of the wrong embryo, maternal or paternal contamination, allele dropout, use of incorrect and inappropriate probes or primers, probe or primer failure and chromosomal mosaicism. Unprotected sex has been mentioned as a cause of adverse outcome not related to technical and human errors. The majority of these causes can be prevented by using robust diagnostic methods within laboratories working to appropriate quality standards. However, diagnosis from a single cell remains a technically challenging procedure, and the risk of misdiagnosis cannot be eliminated.
Opini AndaKlik untuk menuliskan opini Anda tentang koleksi ini!

Kembali
design
 