Exact Analytical Expressions for Relay Feed Back Responses - Second Order Plus Dead Time Processes
Oleh:
Panda, R.C.
;
Yu, Cheng-Ching
Jenis:
Article from Article
Dalam koleksi:
Final Program and Book of Abstracts: The 4th Asian Control Conference, September 25-27, 2002 (Sep. 2002)
,
page 250-255.
Topik:
Exact Analytical
;
Relay Feed Back Responses
;
Dead Time Processes
Fulltext:
AC021681.PDF
(235.14KB)
Isi artikel
Relay feed back tests are carried out on second order plus dead time processes with different time delay and different damping coefficients. The shapes of relay responses are used to classify or categorize the systems. The relay outputs from over damped, critically damped and under damped systems are modeled mathematically in time domain. These analytical expressions are useful to identify unknown system parameters. This method can be extended for higher order systems also.