Pengaruh Diameter dan Ketebalan Pasir Dalam Saringan Pasir Lambat Terhadap Penurunan Kadar Besi
Oleh:
Darsono, Valentinus
;
Sutomo, Teguh
Jenis:
Article from Journal - ilmiah nasional
Dalam koleksi:
Jurnal Teknologi Industri vol. 6 no. 4 (Oct. 2002)
,
page 213-224.
Topik:
Slow Sand Filter
;
Sand Diameter
;
Sand Layer Thickness
Ketersediaan
Perpustakaan Pusat (Semanggi)
Nomor Panggil:
JJ83.3
Non-tandon:
1 (dapat dipinjam: 0)
Tandon:
tidak ada
Lihat Detail Induk
Isi artikel
The water from Maguwoharjo well contain Fe which exceed drinking water standard, that inhibitants can not use the water as drinking water. This research is done to reduce Fe with slow sand filter. The methood can reduce Fe from 1.170 ppm (above drinking water standard) to 0.127 ppm (below drinking water standard) using sand layer diameter 0.297 mm and sand thicness 90 cm.