Anda belum login :: 03 Jun 2025 12:23 WIB
Detail
ArtikelA Pooled Analysis of Data Comparing Sirolimus-Eluting Stents with Bare-Metal Stents  
Oleh: Spaulding, Christian ; Daemen, Joost ; Boersma, Eric ; Cutlip, Donald E ; Serruys, Patrick W.
Jenis: Article from Journal - ilmiah internasional
Dalam koleksi: The New England Journal of Medicine (keterangan: ada di Proquest) vol. 356 no. 10 (Mar. 2007), page 989.
Ketersediaan
  • Perpustakaan FK
    • Nomor Panggil: N08.K.2007.02
    • Non-tandon: 1 (dapat dipinjam: 0)
    • Tandon: tidak ada
    Lihat Detail Induk
Isi artikelBACKGROUND Although randomized studies have shown a beneficial effect of drug-eluting stents in reducing the risk of repeated revascularization, these trials were underpowered to compare rates of death and myocardial infarction. The long-term safety of drug-eluting stents has been questioned recently. METHODS We performed a pooled analysis of1748 patients in four randomized trials evaluating the safety of irolimus-eluting stents as compared with bare-metal stents. Patientlevel data were obtained and analyzed by independent statisticians at two academic institutions. The primary safety end point was survival at 4 years. We tested for heterogeneities in treatment effect in patient subgroups. RESULTS The survival rate at 4 years was 93.3% in the sirolimus-stent group, as compared with 94.6% in the bare-metal-stent group (hazard ratio for death, 1.24; 95% confidence interval [Cn, 0.84 to 1.83; P=0.28). In the 428 patients with diabetes, a significant difference in the survival rate was observed in favor of the bare-metal-stent group over the sirolimus-stent group (95.6% vs. 87.8%; hazard ratio for death in the sirolimus-stent group, 2.9; 95% CI, 1.38 to 6.10; P=0.008). The lower survival rate among patients with diabetes who were treated with sirolimus-eluting stents was due to increased numbers of deaths from both cardiovascular and noncardiovascular causes. No difference in survival rate was detected among the patients without diabetes. Rates of myocardial infarction and stent thrombosis were similar in the two groups. CONCLUSIONS In a pooled analysis of data from four trials comparing sirolimus-eluting stents and bare-metal stents, no significant differences were found between the two treatments in rates of death, myocardial infarction, or stent thrombosis. (ClinicaITrials.gov numbers, NCT00233805, NCT00381420, NCT00232765, and NCTOO235144.)
Opini AndaKlik untuk menuliskan opini Anda tentang koleksi ini!

Kembali
design
 
Process time: 0 second(s)