Anda belum login :: 17 Feb 2025 14:26 WIB
Home
|
Logon
Hidden
»
Administration
»
Collection Detail
Detail
Linear and Quasi-Linear Viscoelastic Characterization of Ankle Ligaments
Oleh:
Funk, J. R.
;
Hall, G. W.
;
Crandall, J. R.
;
Pilkey, W. D.
Jenis:
Article from Bulletin/Magazine
Dalam koleksi:
Journal of Biomechanical Engineering vol. 122 no. 1 (2000)
,
page 15-22.
Topik:
quasi experimentation
;
quasi
;
linear
;
viscoelastic
;
characterization
;
ankle
;
ligaments
Ketersediaan
Perpustakaan Pusat (Semanggi)
Nomor Panggil:
JJ52.1
Non-tandon:
1 (dapat dipinjam: 0)
Tandon:
tidak ada
Lihat Detail Induk
Isi artikel
The objective of this study was to produce linear and non linear viscoelastic models of eight major ligaments in the human ankle / foot complex for use in computer models of the lower extremity. The ligaments included in this study were the anterior talofibular (ATaF), anterior tibiofibular (ATiF), anterior tibiotalar (ATT), calcaneofibular (CF), posterior talofibular (PTaF), posterior tibiofibular (PTiF), posterior tibiotalar (PTT), and tibiocalcaneal (TiC) ligaments. Step relaxation and ramp tests were performed. Back - extrapolation was used to correct for vibration effects and the error introduced by the finite rise time in step relaxation tests. Ligament behaviour was found to be non linear viscoelastic, but could be adequately modeled up to 15 percent strain using Fung's quasilinear viscoelastic (QLV) model. Failure properties and the effects of preconditioning were also examined.