Device-related Infections in Children
Oleh:
Smith, Michael J.
;
Shah, Samir S.
;
Zaoutis, Theoklis E.
Jenis:
Article from Journal - ilmiah internasional
Dalam koleksi:
Pediatric Clinics of North America vol. 52 no. 04 (Aug. 2005)
,
page 1189.
Ketersediaan
Perpustakaan FK
Nomor Panggil:
P13.K.2005.04
Non-tandon:
1 (dapat dipinjam: 0)
Tandon:
tidak ada
Lihat Detail Induk
Isi artikel
Management of devance-releated infections includes device removal for some catheter-related bloodstream infections and all vetri culoperitoneal shunt-related infections. The isolations of certain organisms (eg, staphylococcus aureus, Candida spp) in children with central catheters should prompt consideration of disseminated infection. Future research may determime the impact of increasing catheter use in non- intensive care hospital settings and in home care. New technoogies, such as antimicrobial-impregnated central venous catheters and ventricular shunts, show promise in reducing the infection rates of these devices.