How To Contain Your Currents : Use Gradient Guards and Charge Channels
Oleh:
Anderson, K. F.
Jenis:
Article from Bulletin/Magazine
Dalam koleksi:
IEEE Instrumentation & Measurement Magazine vol. 1 no. 3 (1998)
,
page 24-27.
Topik:
Temperature Gradient
;
gradient guards
;
channels
Ketersediaan
Perpustakaan Pusat (Semanggi)
Nomor Panggil:
II47.1
Non-tandon:
1 (dapat dipinjam: 0)
Tandon:
tidak ada
Lihat Detail Induk
Isi artikel
The classical driven - guard principle applies only to electronic circuit regions that contain a single potential. But a driven outer shield can effectively guard regions within an inner shield that contain a potential gradient. The gradient - guard configuration contains charges within an inner guard and the charge - channel configuration assures that the current entering a conductor at one end will all exit the conductor at its other end even when the conductor and its shields are imbedded in poor insulation resistance to ground.