ArtikelHeat Transfer in A Radially Rotating Four-Pass Serpentine Channel With Staggered Half-V Rib Turbulators  
Oleh: Hwang, G. J. ; Tzeng, S. C. ; Mao, C. P. ; Soong, C. Y.
Jenis: Article from Bulletin/Magazine
Dalam koleksi: Journal of Heat Transfer vol. 123 no. 1 (Feb. 2001), page 39-50.
Topik: rotating; heat transfer; rotating four - pass; serpentine - channel; half - V rib; turbulators
Ketersediaan
  • Perpustakaan Pusat (Semanggi)
    • Nomor Panggil: JJ90.4
    • Non-tandon: 1 (dapat dipinjam: 0)
    • Tandon: tidak ada
    Lihat Detail Induk
Isi artikelThe present work is concerned with experimental investigation of the convective heat transfer in a radially rotating four - pass serpentine channel. Two types of staggered half - V rib turbulators are considered to examine their effects on heat transfer enhancement. The coolant air is pressurized and pre - cooled to compensate for the low rotating rate and low temperature or density difference in key parameters of thermal and flow characteristics. The geometric dimensions are fixed, whereas the ranges of the thermal and flow parameters in the present measurements are 20,000 <= Re <= 4,000, 0 <= Ro <= 0.21, and Gr / Re(2) ~ O (10(–2)). The present results disclose the effects of the pressurized flow, rib arrangement, channel rotation, and centrifugal buoyancy on the local heat transfer in each passage of the channel. Finally, the present data are fitted on correlation equations for evaluation of local heat transfer in the rotating four - pass ribbed channel configurations considered.
Opini AndaKlik untuk menuliskan opini Anda tentang koleksi ini!

Kembali
design
 