Enhanced Heat Transfer Characteristics of Viscous Liquid Flows in A Chevron Plate Heat Exchanger
Oleh:
Muley, A.
;
Manglik, R. M.
;
Metwally, H. M.
Jenis:
Article from Bulletin/Magazine
Dalam koleksi:
Journal of Heat Transfer vol. 121 no. 4 (Nov. 1999)
,
page 1011-1017.
Topik:
heat exchanger
;
heat transfer
;
characteristics
;
viscous liquid flows
;
chevron plate
;
heat exchanger
Ketersediaan
Perpustakaan Pusat (Semanggi)
Nomor Panggil:
JJ90.1
Non-tandon:
1 (dapat dipinjam: 0)
Tandon:
tidak ada
Lihat Detail Induk
Isi artikel
Steady - state heat transfer and pressure drop data for single - phase viscous fluid flows (2 <= Re <= 400) in a single - pass U - type counterflow plate heat exchanger (PHE) with chevron plates are presented. With vegetable oil as test fluid (130 < Pr < 290), three different plate arrangements are employed: two symmetric (b = 30 deg/30 deg and 60 deg / 60 deg) and one mixed (b = 30 deg / 60 deg). The effects of chevron angle b, corrugation aspect ratio j, and flow conditions (Re, Pr, µ / µw on Nu and f characteristics of the PHE are delineated. The results show a rather complex influence of plate surface corrugations on the enhanced thermal - hydraulic behavior. Relative to the performance of equivalent flat - plate packs, chevron plates sustain up to 2.9 times higher heat transfer rates on a fixed geometry and constant pumping power basis, and require up to 48 percent less surface area for the fixed heat load and pressure drop constraint.
Opini Anda
Klik untuk menuliskan opini Anda tentang koleksi ini!
Kembali
Process time: 0.015625 second(s)