Critical Heat Flux of Multi-Nozzle Spray Cooling
Oleh:
Lanchao, Lin
;
Ponnappan, Rengasamy
Jenis:
Article from Bulletin/Magazine
Dalam koleksi:
Journal of Heat Transfer vol. 126 no. 3 (Jun. 2004)
,
page 482-484.
Topik:
spray
;
critical heat flux
;
multi - nozzle
;
spray cooling
Ketersediaan
Perpustakaan Pusat (Semanggi)
Nomor Panggil:
JJ90.8
Non-tandon:
1 (dapat dipinjam: 0)
Tandon:
tidak ada
Lihat Detail Induk
Isi artikel
Tiny nozzles are developed that are capable of creating the swirling flow necessary to generate a full cone spray. Eight miniature nozzles are embedded in a multi - nozzle plate used to generate a spray array for the cooling of high heat flux laser diodes. The target spray cooling area is a 1 × 2 cm2 flat surface of a copper heater plate. A closed loop spray cooling test setup is established. FC-87, FC-72 and methanol are used as the working fluids. Critical heat flux (CHF) is experimentally investigated at various spray saturation temperatures and nozzle pressure drops (from 0.690 bar to 3.10 bar). It is demonstrated that the spray cooler can reach the CHF levels up to 91.5 W / cm(2) with FC-87 and 490 W / cm(2) with methanol.