Pengukuran Konsentrasi Gas Randon Di Perumahan UNAND Griya Andalas Kotamadya Padang Dengan Menggunakan Detektor CR-39
Oleh:
Abbas, Alwis
;
Milvita, Dian
;
Basa, Sri Mulyadi Dt.
Jenis:
Article from Journal - ilmiah nasional
Dalam koleksi:
Andalas: Jurnal Penelitian vol. 15 no. 34 (Jan. 2001)
,
page 40-46.
Topik:
measurement
;
radon gas
Ketersediaan
Perpustakaan PKPM
Nomor Panggil:
A67
Non-tandon:
1 (dapat dipinjam: 0)
Tandon:
tidak ada
Lihat Detail Induk
Isi artikel
This research is purposed to measure Radon gas Concentration in Unand Griya Andalas complex. It distance about two kilometers from Cement Padang Factory. The measurements were carried out by using CR-39 detector. The measurement of Radon gas concentration was done indoors and outdoors, the result of measurement shows that concentration of Radon gas indoors more high than outdoors. The Radon gas concentration indoors is 0, 54 pCi/l until 6, 77 pCi/l and outdoors is 0,43 pCi/l until 2,96 pCi/l.