Anda belum login :: 27 Nov 2024 09:00 WIB
Home
|
Logon
Hidden
»
Administration
»
Collection Detail
Detail
Standardized Mixed-Meal Tolerance and Arginine Stimulation Tests Provide Reproducible and Complementary Measures of ß-Cell Function: Results From the Foundation for the National Institutes of Health Biomarkers Consortium Investigative Series
Oleh:
Shankar, Sudha S.
;
Vella, Adrian
;
Raymond, Ralph H.
;
Staten, Myrlene A.
;
Fryburg, David A.
Jenis:
Article from Journal - ilmiah internasional
Dalam koleksi:
Diabetes Care vol. 39 no. 09 (Sep. 2016)
,
page 1602-1613.
Topik:
ß-Cell Function
;
BCF
;
Type 2 Diabetes
;
T2D
Ketersediaan
Perpustakaan FK
Nomor Panggil:
D05.K
Non-tandon:
1 (dapat dipinjam: 0)
Tandon:
tidak ada
Lihat Detail Induk
Isi artikel
OBJECTIVE Standardized, reproducible, and feasible quantification of ß-cell function (BCF) is necessary for the evaluation of interventions to improve insulin secretion and important for comparison across studies. We therefore characterized the responses to, and reproducibility of, standardized methods of in vivo BCF across different glucose tolerance states. RESEARCH DESIGN AND METHODS Participants classified as having normal glucose tolerance (NGT; n = 23), prediabetes (PDM; n = 17), and type 2 diabetes mellitus (T2DM; n = 22) underwent two standardized mixed-meal tolerance tests (MMTT) and two standardized arginine stimulation tests (AST) in a test-retest paradigm and one frequently sampled intravenous glucose tolerance test (FSIGT). RESULTS From the MMTT, insulin secretion in T2DM was >86% lower compared with NGT or PDM (P < 0.001). Insulin sensitivity (Si) decreased from NGT to PDM (~50%) to T2DM (93% lower [P < 0.001]). In the AST, insulin secretory response to arginine at basal glucose and during hyperglycemia was lower in T2DM compared with NGT and PDM (>58%; all P < 0.001). FSIGT showed decreases in both insulin secretion and Si across populations (P < 0.001), although Si did not differ significantly between PDM and T2DM populations. Reproducibility was generally good for the MMTT, with intraclass correlation coefficients (ICCs) ranging from ~0.3 to ~0.8 depending on population and variable. Reproducibility for the AST was very good, with ICC values >0.8 across all variables and populations. CONCLUSIONS Standardized MMTT and AST provide reproducible and complementary measures of BCF with characteristics favorable for longitudinal interventional trials use.
Opini Anda
Klik untuk menuliskan opini Anda tentang koleksi ini!
Kembali
Process time: 0.015625 second(s)