ArtikelA Universal, Nonintrusive Method for Correcting The Reading of A Flow Meter in Pipe Flow Disturbed By Installation Effects  
Oleh: Gersten, K. ; Merzkirch, W. ; Wildemann, C.
Jenis: Article from Bulletin/Magazine
Dalam koleksi: Journal of Fluids Engineering vol. 124 no. 3 (2002), page 650-656.
Topik: installation; universal; non intrusive method; reading; flow meter; pipe flow; installation effects
Ketersediaan
  • Perpustakaan Pusat (Semanggi)
    • Nomor Panggil: JJ89.3
    • Non-tandon: 1 (dapat dipinjam: 0)
    • Tandon: tidak ada
    Lihat Detail Induk
Isi artikelA method is described that allows the correction of the reading of a flow meter that is exposed to pipe flow disturbed by installations upstream of the meter. The method is aimed at minimizing the distance between installation and meter and is based on characterizing the flow by "fundamental" disturbances, physically interpretable as vortical structures, and on the detection of these disturbances by a measuring device located slightly upstream of the meter. A functional relationship between fundamental disturbances and "error shift" of the meter is postulated, and its existence is demonstrated by a number of experiments. It is concluded that the correction method is applicable to any type of installation and flow meter.