Anda belum login :: 27 Nov 2024 04:54 WIB
Detail
ArtikelApplication of Boundary Layer Fences and Vortex Generators in Improving Performance of S-Duct Diffusers  
Oleh: Mishra, Sourabh ; Pradeep, A. M. ; Sullerey, R. K.
Jenis: Article from Bulletin/Magazine
Dalam koleksi: Journal of Fluids Engineering vol. 124 no. 1 (2002), page 136-142.
Topik: Performance; application; boundary layer; generators; performance; s - duct diffusers
Ketersediaan
  • Perpustakaan Pusat (Semanggi)
    • Nomor Panggil: JJ89.4
    • Non-tandon: 1 (dapat dipinjam: 0)
    • Tandon: tidak ada
    Lihat Detail Induk
Isi artikelAn experimental investigation was undertaken to study the effect of various fences and vortex generator configurations in reducing the exit flow distortion and improving total pressure recovery in two - dimensional S - duct diffusers of different radius ratios. Detailed measurements including total pressure and velocity distribution, surface static pressure, skin friction, and boundary layer measurements were taken in a uniform inlet flow at a Reynolds number of 7.8 × 10(5). These measurements are presented here along with static pressure rise, distortion coefficient, and the transverse velocity vectors at the duct exit determined from the measured data. The results indicate that substantial improvement in static pressure rise and flow quality is possible with judicious deployment of fences and vortex generators.
Opini AndaKlik untuk menuliskan opini Anda tentang koleksi ini!

Kembali
design
 