Anda belum login :: 23 Nov 2024 10:02 WIB
Detail
ArtikelFriction Factor in U-Type Undulated Pipe Flow  
Oleh: Wojtkowiak, J. ; Popiel, C. O.
Jenis: Article from Bulletin/Magazine
Dalam koleksi: Journal of Fluids Engineering vol. 122 no. 2 (2000), page 260-263.
Topik: friction; friction; factor; u - type; pipe flow
Ketersediaan
  • Perpustakaan Pusat (Semanggi)
    • Nomor Panggil: JJ89.1
    • Non-tandon: 1 (dapat dipinjam: 0)
    • Tandon: tidak ada
    Lihat Detail Induk
Isi artikelMeasurements of pressure losses in a U - type undulated hydraulically smooth wall pipe, having constant radius curvature, are presented. The effect of the dimensionless curvature radius 2R/d on the Darcy friction factor was investigated in the range of the Reynolds number from about 50 to 10,000 and for the dimensionless pipe curvature radiuses 2R/d = 6.62, 7.95, 11.13, 16.03, 22.58, and 27.85. A smooth transition from laminar to turbulent region in the friction factor versus Reynolds number plot, typical for curved pipe flows, was observed. The experimental data were correlated with the relatively simple equation using new Dean number De(n) = Re * (De(n) = Re * (d/2R) : ln(f(w) * Re/64) = a + b(ln(De(n)))(2), which is not valid for larger values of De(n) and 2R/d, e. g., for De(n) > 200 at 2R/d = 22.58, and for De(n) > 70 at 2R/d = 27.85. The new Dean number, below which the influence of the pipe curvature in comparison to the straight tube was not seen, is Den <= -3.
Opini AndaKlik untuk menuliskan opini Anda tentang koleksi ini!

Kembali
design
 
Process time: 0.03125 second(s)