Anda belum login :: 23 Nov 2024 04:42 WIB
Detail
ArtikelContent analysis Silica (SiO2) in process water determeralisation with 4M method  
Oleh: Sukanta ; Janaka, Hendra ; Permana, Rian Arie
Jenis: Article from Proceeding
Dalam koleksi: PROCEEDING The 8th International Seminar on Industrial Engineering and Management (8th ISIEM). Atria Hotel & Conference, Malang, Indonesia March 17 – 19, 2015, page QM-51.
Topik: Silica (SiO2); Quality Control; 4M Analysis; Boilers
Fulltext: Paper 82 Sukanta - Karawang Singaperbangsa University.pdf (274.72KB)
Isi artikelThis study aimed to analyze whether demineralized water is appropriate or not with the standards and also look for the cause of demineralized water quality parameters are not in accordance with the standards set by the company. Demineralized water is used as boiler feed water into the main ingredient manufacture of steam and very dangerous if water quality parameters exceed the prescribed standards. Sampling the data and methods used for the analysis of water quality with 4M method. 4M method is a method of analyzing the causes of a problem with categorizing the causes into four (Empat) factors: Man, Material, Method and Machine. The results of this study indicate that the index of the ability of the process to phase in the process of Strong Base Anion (SBA), Mixed Bed (MB) and Tank that the process capability index is below one, Cpk = 1 means that the ability of the production process is less well demineralized water, where the water quality demineralized on the stages of the production process beyond the control of the gold standard parameter company. From the analysis that the problem parameters 4M silica (SiO2) in the process of demineralized water is not in accordance with the standards that are caused by factors is the most dominant factor that method on how to care machines and other facilities that should be done periodically .
Opini AndaKlik untuk menuliskan opini Anda tentang koleksi ini!

Kembali
design
 
Process time: 0.015625 second(s)