ArtikelRemoval of Microorganisms in Drinking Water using a Pulsed High Voltage  
Oleh: Darwison ; Waldi, Eka Putra ; Desmiarti, Reni ; Hazmi, Ariadi
Jenis: Article from Journal - ilmiah nasional - terakreditasi DIKTI
Dalam koleksi: Journal of Engineering and Technological Sciences vol. 45 no. 01 (2014), page 001-008.
Topik: Drinking water; fecal coliforms; pulsed high voltage; total coliforms; water pollutant.
Fulltext: 612-1883-1-SM.pdf (219.13KB)
Isi artikelA pulsed high voltage was used to remove microorganisms in drinking water. The effects of the pulsed high voltage on pH, conductivity, temperature and oxidation reduction potential (ORP) of the drinking water were investigated. The observed results show that the removal efficiency with respect to fecal coliforms and total coliforms increased with the increase of the pulsed high voltage. The removal efficiency for microorganisms such as fecal coliforms and total coliforms was in the range 25-100% and 44-100%, respectively, after the water was exposed to a pulsed high voltage of 5-10 kV for 60 minutes. An increase of the pulsed high voltage caused a decrease in the conductivity and ORP with operational time.