Anda belum login :: 23 Nov 2024 08:08 WIB
Home
|
Logon
Hidden
»
Administration
»
Collection Detail
Detail
Blood clearance of Howell–Jolly bodies in an experimental autogenic splenic implant model
Oleh:
Marques, R.G.
;
Lucena, S.B.S.G.
;
Caetano, C.E.R.
;
Sousa, V. Oliveira de
Jenis:
Article from Article - diterbitkan di jurnal ilmiah internasional
Dalam koleksi:
BJS: British Journal of Surgery vol. 101 no. 07 (Jun. 2014)
,
page 820-827.
Topik:
splenectomy
;
abdominal trauma
;
implant
;
total splenectomy
;
autogenic spleen implant
Ketersediaan
Perpustakaan FK
Nomor Panggil:
B15.K
Non-tandon:
1 (dapat dipinjam: 0)
Tandon:
tidak ada
Lihat Detail Induk
Isi artikel
Background Autogenic splenic implant (ASI) is one of the few alternatives for preservation of splenic tissue when total splenectomy is inevitable. The aim of this study was to determine the morphological and functional regeneration of ASIs, as indicated by the clearance of Howell–Jolly (HJ) bodies, in an experimental model. Methods Ninety-nine male Wistar rats were divided into three groups: sham-operated (group 1), total splenectomy alone (group 2), and total splenectomy combined with ASI (group 3). Animals in group 3 were further allocated to nine subgroups of nine rats each, and analysed at different time points (1, 4, 8, 12, 16, 20, 24, 28 and 32?weeks after surgery). Blood smears were prepared at predetermined times for detection of HJ bodies. Morphological regeneration of tissue in the ASI was analysed by histology. Results At 1?week, the regenerated mass corresponded to about 7 per cent of the tissue implanted, reaching approximately 54 per cent at 24?weeks. The HJ body levels were increased in groups 2 and 3 until 8?weeks after surgery, following which levels in the ASI group became similar to those in the sham-operated group. HJ bodies were difficult to detect when a level of 22·5 per cent of regenerated ASI mass was reached. Conclusion Functional regeneration of ASIs occurred from 8 weeks after surgery. When 22·5 per cent of regenerated ASI mass was reached almost no HJ bodies could be observed in the bloodstream, resembling a spleen in situ. Surgical relevance Splenectomy has been practised routinely, both in the emergency setting and as a therapeutic elective procedure. There is a correlation between asplenia/hyposplenia and the occurrence of fulminant sepsis, underlining the importance of developing surgical methods for preserving splenic function. Both clinical and experimental studies have shown at least partial morphological and functional regeneration of autogenic splenic implants (ASIs). Experimental studies investigating the immunoprotective effect of ASIs, based mostly on exposure of animals to various bacteria, have demonstrated that ASIs can increase the rate of bacterial clearance and decrease mortality from sepsis. Clinical studies have shown their ability to remove colloidal substances and altered erythrocyte corpuscular inclusions, such as Howell–Jolly, Heinz and Pappenheimer bodies, from the bloodstream. In this experimental study the functional and morphological regeneration of ASIs was studied over time in rats.
Opini Anda
Klik untuk menuliskan opini Anda tentang koleksi ini!
Kembali
Process time: 0.015625 second(s)