Anda belum login :: 23 Nov 2024 06:09 WIB
Home
|
Logon
Hidden
»
Administration
»
Collection Detail
Detail
A Single Measurement of Serum Phylloquinone Is an Adequate Indicator of Long-Term Phylloquinone Exposure in Healthy Older Adults
Oleh:
Presse, Nancy
;
Gaudreau, Pierrette
;
Greenwood, Carol E.
;
Kergoat, Marie-Jeanne
Jenis:
Article from Journal - ilmiah internasional
Dalam koleksi:
JN: The Journal of Nutrition vol. 142 no. 10 (Oct. 2012)
,
page 1910-1916.
Topik:
Methodology and Mathematical Modeling
;
long-term phylloquinone exposure
Ketersediaan
Perpustakaan FK
Nomor Panggil:
J42.K.2012.02
Non-tandon:
1 (dapat dipinjam: 0)
Tandon:
tidak ada
Lihat Detail Induk
Isi artikel
Assessment of long-term phylloquinone exposure is challenging in studies investigating vitamin K in health. Data are equivocal as to whether a single measurement of circulating phylloquinone would be adequate. The primary purpose of the present study was to validate the use of a single measurement of serum phylloquinone as a surrogate for long-term phylloquinone exposure in healthy older adults. Using data from the Québec Longitudinal Study on Nutrition and Successful Aging, the objectives were to: 1) determine the reproducibility of circulating phylloquinone over 2 y (n = 234); 2) calculate how a single measurement would rank or classify individuals and attenuate the regression coefficient between circulating phylloquinone and a health outcome; and 3) investigate the association of a single measurement of serum phylloquinone with long-term phylloquinone intakes assessed over the year prior to the blood draw (n = 228). The variance analysis based on 2 blood samples showed a fair to good reproducibility for serum phylloquinone (intra-class correlation = 0.49). The correlation coefficient between the ranking of individuals based on a single measurement of circulating phylloquinone and the “true” ranking would be 0.70. The multiple regression analysis showed that long-term phylloquinone intake was the strongest predictor of serum phylloquinone (t = 4.94; P < 0.001). The partial correlation coefficient (r = 0.32) was comparable with those reported in studies where blood sampling and diet recording were juxtaposed and/or multiple blood samples were used. The present study provides evidence that the use of a single measurement of circulating phylloquinone is adequate for assessing long-term phylloquinone exposure in healthy older adults.
Opini Anda
Klik untuk menuliskan opini Anda tentang koleksi ini!
Kembali
Process time: 0.015625 second(s)