Anda belum login :: 23 Nov 2024 04:11 WIB
Home
|
Logon
Hidden
»
Administration
»
Collection Detail
Detail
Industrial Implementation of Aluminum Trihydrate-Fiber Composition for Fire Resistance and Mechanical Properties in Glass-Fiber-Reinforced Polymer Roofs (article of Polymers 2022 Vol.14 No.7; 1273)
Bibliografi
Author:
Zainudin, Mohammad
;
Diharjo, Kuncoro
;
Kaavessina, Mujtahid
;
Setyanto, Djoko
;
Ubaidillah
Topik:
composite
;
aluminium trihydrate (ATH)
;
unsaturated polyester resin
;
mechanical properties
;
fire-resistant
;
JABFUNG-FT-DJS-2022
Bahasa:
(EN )
Penerbit:
Multidisciplinary Digital Publishing Institute (MDPI)
Tempat Terbit:
Basel, Switzerland
Tahun Terbit:
2022
Jenis:
Article - diterbitkan di jurnal ilmiah internasional
Fulltext:
2022 polymers-14-01273.pdf
(2.79MB;
6 download
)
Abstract
It is difficult to obtain suitable fire resistance and mechanical properties for glass-fiber-reinforced polymer (GFRP) roof material in industrial applications. Although some efforts to improve the fire resistance properties of GFRP have been carried out, in practice this sometimes degrades the mechanical properties. Therefore, the base materials, such as filler and reinforcing fiber, must be appropriately combined to simultaneously improve both fire resistance and mechanical properties. The present study examines improvements in GFRP roof material by investigating the effect of aluminium trihydrate (ATH) as a filler and the combination of a chopped strand mat (CSM) with woven roving (WR) and stitched mat (STM) fibers as the reinforcement in a composite GFRP roof structure. The roof samples were prepared following industrial machine standards using the specified materials. The mechanical properties of GFRP were evaluated using tensile, flexural and impact tests, following ASTM D638, ASTM D790 and ASTM D256 standards, respectively. The fire properties were examined through fire tests following the ASTM D635 standard. The results show that the GFRP roof composed of CSM/WR fibers had a 40% higher tensile strength (103.5 MPa) compared with the GFRP roof without CSM fibers (73.8 MPa). The flexural strength of the GFRP roof with CSM/WR fibers was also 57% higher than the roof without fibers, with a ratio of 315.61 MPa to 201 MPa. With the use of CSM/WR fibers, the fire resistance also increased by 23%, resulting in a ratio of 4.31 mm/min to 5.32 mm/min. These results demonstrate that the combination of CSM/WR fibers as a reinforcement would be an excellent option for producing an improved GFRP roof with better industrial properties, especially when producing improved GFRP roofs using a continuous lamination machine.