ArtikelPerformance of GaAs Microbridge Thermocouple Infrared Detectors  
Oleh: Ahmed, H. ; Chong, Nui ; Srinivas, T. A. S.
Jenis: Article from Bulletin/Magazine
Dalam koleksi: Journal of Microelectro Mechanical System vol. 6 no. 2 (1997), page 136-141.
Topik: DETECTORS; performance; GaAs; microbridge; thermocouple; infrared; detectors
Ketersediaan
  • Perpustakaan Pusat (Semanggi)
    • Nomor Panggil: JJ30.2
    • Non-tandon: 1 (dapat dipinjam: 0)
    • Tandon: tidak ada
    Lihat Detail Induk
Isi artikelGaAs microbridge thermocouples with lengths ranging from 40 to 650 µm and operating at room temperature have been fabricated for the detection of infrared radiation. A CO2 laser of a 10.6 µm wavelength was used to characterize the performance of the detectors in air and in vacuum. A responsivity of 4.2 V/W with a corresponding detectivity D* = 8 × 10(6) cm Hz(1/2)/W and a time constant of 2.2 ms have been measured in vacuum for 650 - µm - long bridges, and a shorter time constant of 50 µs was obtained for 40 - µm - long bridges. An analytic thermal transport model has been used to simulate the operation of the sensors. The heat - transfer coefficient has been evaluated by comparing the data from air and vacuum measurements. The spectral response and the absorbance of the microbridge have also been presented.