Anda belum login :: 23 Nov 2024 18:24 WIB
Detail
ArtikelTHE ADVANTAGE OF OIL CONTENT IN INJECTION WATER DETERMINATION BEFORE IMPLEMENTATION OF WATERFLOOD IN OILFIELD  
Oleh: Makmur, Tjuwati
Jenis: Article from Journal - ilmiah nasional
Dalam koleksi: Lemigas Scientific Contributions to Petroleum Science & Technology vol. 33 no. 01 (May 2010), page 35.
Topik: Oil contents; Injection water; Methodology; Emulsion block; Reverse demulsifier
Ketersediaan
  • Perpustakaan PKPM
    • Nomor Panggil: L15
    • Non-tandon: 1 (dapat dipinjam: 0)
    • Tandon: tidak ada
    Lihat Detail Induk
Isi artikelBefore implementation of water flooding in oilfield, it will be good to determine oil content in the injection water. The results of laboratory tests provide valuable and useful information, firstly, whether reverse demulsifier is required or not to reduce oil content in water. Secondly, the test results can select the effective reverse demulsifier. S1 and S2 injection water contain very low oil content, so it is not necessary to add reverse demulsifier in the both injection water. High oil content is obtained in S3 injection. The 50 mg/L DKM reverse demulsifier does not work effectively to reduce oil content in the S3 injection water. Whereas, the 50 mg/L Prolab reverse demulsifier is effective and able to reduce oil content sharply in the S3 injection water with 95.46 % efficiency
Opini AndaKlik untuk menuliskan opini Anda tentang koleksi ini!

Kembali
design
 
Process time: 0.015625 second(s)