BukuPENGARUH TEMPERATUR DAN WAKTU PLASMA NITRIDING TERHADAP PERBAIKAN KUALITAS LAPISAN HARD CHROME
Bibliografi
Author: Basoeki, Prita Dewi (Advisor); Januar, Mochamad (Advisor); 'Daniel
Topik: hard chrome plating; micro crack; plasma nitriding; layer tickness; CrN and Cr2N
Bahasa: (ID )    
Penerbit: Program Studi Teknik Mesin Fakultas Teknik Unika Atma Jaya     Tempat Terbit: Jakarta    Tahun Terbit: 2019    
Jenis: Theses - Undergraduate Thesis
Fulltext: Tugas Akhir_Daniel_2014-041-053_12014001314.pdf (3.04MB; 4 download)
Abstract
In the process of hard chrome plating is often found defects in the form of micro cracks due to the shrinkage of the volume of the layer so that it induces tensile tensile stresses that cause cracks. The emergence of micro cracks causes a decrease in corrosion resistance on the surface of the workpiece. In this study will be repeated by plasma nitriding method. Re-coating is done using temperature variations at 350°C, 400°C, and 450°C as well as variations in holding time for 2, 4, and 5 hours. The coating results of hard chrome plating and coating repairs with the plasma nitriding process are characterized by hard and metallographic tests. From the results of characterization it is known that at a temperature of 450°C and a holding time of 5 hours has the highest hardness with an optimal thickness layer 7.53 µm, but the CrN compound has not been fully formed.