Anda belum login :: 17 Feb 2025 13:28 WIB
Home
|
Logon
Hidden
»
Administration
»
Collection Detail
Detail
How Bolted Joints Behave Under Internal Loads
Oleh:
Lee, Moo-Zung
Jenis:
Article from Bulletin/Magazine - ilmiah internasional
Dalam koleksi:
Machine Design (Soft Copy ada dalam http://search.proquest.com/) vol. 82 no. 19 (Nov. 2010)
,
page 77-79.
Topik:
Thermal loads
;
Thermal expansion
;
Constrained bar pair
;
Heated-Bolt Preloading
Ketersediaan
Perpustakaan Pusat (Semanggi)
Nomor Panggil:
MM44.63
Non-tandon:
1 (dapat dipinjam: 0)
Tandon:
tidak ada
Lihat Detail Induk
Isi artikel
Understanding the structural behavior of bolted joints is essential for sound design. For instance, forces that overcome preload can cause bolted assemblies to leak or fail. In a previous article, we learned about the effects of external loads ("How external loads affect bolted joints," MACHINE DESIGN, April 22, 2010, p. 58-60). Now lets consider the behavior of bolted joints under various internal loads.