Anda belum login :: 23 Nov 2024 15:42 WIB
Detail
ArtikelSupplementation with a recombinant human chorionic gonadotropin microdose leads to similar outcomes in ovarian stimulation with recombinant follicle-stimulating hormone using either a gonadotropin-releasing hormone agonist or antagonist for pituitary suppression  
Oleh: Cavagna, Mario ; Maldonado, Luiz Guilherme Louzada ; Bonetti, Tatiana Carvalho de Souza
Jenis: Article from Journal - ilmiah internasional
Dalam koleksi: Fertility and Sterility (keterangan: ada di ClinicalKey) vol. 94 no. 01 (Jun. 2010), page 167-172.
Topik: GnRH agonists; GnRH antagonists; recombinant FSH; recombinant hCG; ICSI
Ketersediaan
  • Perpustakaan FK
    • Nomor Panggil: F02.K.2010.04
    • Non-tandon: 1 (dapat dipinjam: 0)
    • Tandon: tidak ada
    Lihat Detail Induk
Isi artikelObjective To compare the outcomes of protocols for ovarian stimulation with recombinant hCG microdose, with GnRH agonists and antagonists for pituitary suppression. Design Prospective nonrandomized clinical trial. Setting A private assisted reproduction center. Patient(s) We studied 182 patients undergoing intracytoplasmic sperm injection (ICSI) cycles, allocated into two groups: GnRH agonist group, in which patients received a GnRH agonist (n = 73), and a GnRH antagonist group, in which patients were administered a GnRH antagonist for pituitary suppression (n = 109). Intervention(s) Pituitary suppression with GnRH agonist or GnRH antagonist. Ovarian stimulation carried out with recombinant FSH and supplemented with recombinant hCG microdose. Main Outcome Measure(s) Total dose of recombinant FSH and recombinant hCG administered; E2 concentrations and endometrial width on the day of hCG trigger; number of follicles aspirated, oocytes and mature oocytes retrieved; fertilization, pregnancy (PR), implantation, and miscarriage rates. Result(s) The total dose of recombinant FSH and recombinant hCG administered were similar between groups, as were the E2 concentrations and endometrial width. The number of follicles aspirated, oocytes, and metaphase II oocytes collected were also comparable. There were no statistically significant differences in fertilization, PR, implantation, and miscarriage rates in the GnRH agonist and GnRH antagonist groups. Conclusion(s) When using recombinant hCG microdose supplementation for controlled ovarian stimulation (COS), there are no differences in laboratory or clinical outcomes with the use of either GnRH antagonist or agonist for pituitary suppression.
Opini AndaKlik untuk menuliskan opini Anda tentang koleksi ini!

Kembali
design
 
Process time: 0.015625 second(s)