Indoor air quality in University X’s Libraries (Physical, chemical and microbial aspects)
Oleh:
Fitria, Laila
;
Wulandari, Ririn Arminsih
;
Hermawati, Ema
;
Susanna, Dewi
Jenis:
Article from Journal - ilmiah nasional - terakreditasi DIKTI
Dalam koleksi:
Makara Seri Kesehatan vol. 12 no. 2 (Dec. 2008)
,
page 76.
Topik:
Mould
;
Indoor Air Quality
;
Library
Ketersediaan
Perpustakaan Pusat (Semanggi)
Nomor Panggil:
MM75.1
Non-tandon:
1 (dapat dipinjam: 0)
Tandon:
tidak ada
Lihat Detail Induk
Isi artikel
The objective of thisresearch was to identify mould in university's library using cross sectional design. The existence of mould and physicaland chemical quality of air in library have been investigated and observed in three faculties; they were in FA, FB, andFC. To identify the mould, it used petri dish in Potato Dextrose Agar medium. There were 6-9 samples from eachlibrary. The temperature in three libraries were higher than standard, the intensity of light were very low in location FBand FC, and the dust concentration in FA was very high. It was found the pathogenic mould; they were Aspergillusfumigatus in FA, Scopulariopsis candida in FB, and Fusarium verticilloides in FC. In general, the physical, chemicaland microbial quality of air in libraries exceeded the legal standard.