Anda belum login :: 23 Nov 2024 03:50 WIB
Home
|
Logon
Hidden
»
Administration
»
Collection Detail
Detail
Outbreak of Adverse Reactions Associated with Contaminated Heparin
Oleh:
Blossom, David B.
;
Kallen, Alexander J.
;
Patel, Priti R.
;
Elward, Alexis
;
Robinson, Luke
Jenis:
Article from Journal - ilmiah internasional
Dalam koleksi:
The New England Journal of Medicine (keterangan: ada di Proquest) vol. 359 no. 25 (Dec. 2008)
,
page 2674.
Ketersediaan
Perpustakaan FK
Nomor Panggil:
N08.K.2008.06
Non-tandon:
1 (dapat dipinjam: 0)
Tandon:
tidak ada
Lihat Detail Induk
Isi artikel
Background In January 2008, the Centers for Disease Control and Prevention began a nationwide investigation of severe adverse reactions that were first detected in a single hemodialysis facility. Preliminary findings suggested that heparin was a possible cause of the reactions. Methods Information on clinical manifestations and on exposure was collected for patients who had signs and symptoms that were consistent with an allergic-type reaction after November 1, 2007. Twenty-one dialysis facilities that reported reactions and 23 facilities that reported no reactions were included in a case–control study to identify facility-level risk factors. Unopened heparin vials from facilities that reported reactions were tested for contaminants. Results A total of 152 adverse reactions associated with heparin were identified in 113 patients from 13 states from November 19, 2007, through January 31, 2008. The use of heparin manufactured by Baxter Healthcare was the factor most strongly associated with reactions (present in 100.0% of case facilities vs. 4.3% of control facilities, P<0.001). Vials of heparin manufactured by Baxter from facilities that reported reactions contained a contaminant identified as oversulfated chondroitin sulfate (OSCS). Adverse reactions to the OSCS-contaminated heparin were often characterized by hypotension, nausea, and shortness of breath occurring within 30 minutes after administration. Of 130 reactions for which information on the heparin lot was available, 128 (98.5%) occurred in a facility that had OSCS-contaminated heparin on the premises. Of 54 reactions for which the lot number of administered heparin was known, 52 (96.3%) occurred after the administration of OSCS-contaminated heparin. Conclusions Heparin contaminated with OSCS was epidemiologically linked to adverse reactions in this nationwide outbreak. The reported clinical features of many of the cases further support the conclusion that contamination of heparin with OSCS was the cause of the outbreak.
Opini Anda
Klik untuk menuliskan opini Anda tentang koleksi ini!
Kembali
Process time: 0.015625 second(s)