Anda belum login :: 27 Nov 2024 11:33 WIB
Detail
BukuPengembangan Metode Pengukuran Antropometri dengan Computerized Image Based System (Cibs) untuk Postur Berdiri
Bibliografi
Author: MELINDA, JESSICA ; Yanto (Advisor)
Topik: Computerized Image Based System; Standing Body Dimensions; The Correction Factor.
Bahasa: (ID )    
Penerbit: Program Studi Teknik Industri Fakultas Teknik Unika Atma Jaya     Tempat Terbit: Jakarta    Tahun Terbit: 2010    
Jenis: Theses - Undergraduate Thesis
Fulltext:
Ketersediaan
  • Perpustakaan Pusat (Semanggi)
    • Nomor Panggil: FTI-572
    • Non-tandon: tidak ada
    • Tandon: 1
 Lihat Detail Induk
Abstract
Anthropometric measurements can use conventional methods and modern methods. This research aims to develop a model of the anthropometric data measurements with Computerized Image Based System (CIBS). The measurement model developed is intended to measure the anthropometric data in standing posture. The expected output of this research is the program Computerized Image Based System (CIBS) is used for the measurement of anthropometric data for standing postures and procedures for anthropometric data measurements with the measurement method CIBS. In this study conducted using support MATLAB software, SPSS 14 and Minitab 14. Application of measurement models developed in the CIBSdimensional
measurement of body stood. Ten standing body dimensions used as the measurement variable. This research was conducted through several stages.
The collection of data using manual measurements taken to percentage of the value of the ratio of each high-dimensional body to body and the program Image-Based Computerized System. The use of photographic techniques is required to
get the input of image data. Measurement model using Image-Based Computerized System was developed to facilitate the anthropometric
measurement techniques. Data processing done on the data from both types of measurements. Tests
conducted include descriptive testing, test normalization and reliability testing. Reliability tests performed to determine the validation of the measurement model CIBS. Reliability test results indicate an invalid value for the three diemnsi body.
High knees, long-range arms to the front, shoulder length hand before a dimension that must be determined correction factor is not valid because of the two types of measurements. Correction factor is used to improve the measurement model has been developed.
Opini AndaKlik untuk menuliskan opini Anda tentang koleksi ini!

Lihat Sejarah Pengadaan  Konversi Metadata   Kembali
design
 
Process time: 0.390625 second(s)