Anda belum login :: 23 Nov 2024 03:12 WIB
Detail
ArtikelRelationship of A1C to Glucose Concentrations in Children With Type 1 Diabetes : Assessments by high-frequency glucose determinations by sensors  
Oleh: Diabetes Research in Children Network Study Group
Jenis: Article from Journal - ilmiah internasional
Dalam koleksi: Diabetes Care vol. 31 no. 03 (Mar. 2008), page 381.
Topik: DCCT; Diabetes Control and Complications Trial ; DirecNet; Diabetes Research in Children Network ; EDIC; Epidemiology of Diabetes Interventions and Complications ; MDI; multiple daily injection
Ketersediaan
  • Perpustakaan FK
    • Nomor Panggil: D05.K.2008.02
    • Non-tandon: 1 (dapat dipinjam: 0)
    • Tandon: tidak ada
    Lihat Detail Induk
Isi artikelOBJECTIVE—Despite the standing of A1C as the most validated and widely used measure for average glycemic control over time, the relationship between A1C and glucose concentrations is not completely understood. The purpose of this Diabetes Research in Children Network (DirecNet) study was to use continuous glucose monitoring data to examine the relationship between A1C and glucose in type 1 diabetes. RESEARCH DESIGN AND METHODS—Forty-eight youth enrolled in studies of the Navigator continuous glucose monitor were encouraged to wear the Navigator sensor at home continuously. A1C was measured at baseline, at 3 months, and at 6 months. Sensor glucose data were directly transmitted via the Internet, assuring that essentially all glucose values were analyzed. RESULTS—Subjects had a median of 112 h/week of Navigator data in the first 3 months and 115 h/week in the second 3 months. The slope of mean glucose over the previous 3 months versus A1C was only 18 mg/dl per 1.0% A1C. Individually, there was substantial variation in the relationship between mean glucose and A1C. A1C was not associated with glucose lability after controlling for mean glucose. Measures of an individual's rate of glycation were moderately correlated at the 3- and 6-month visits. CONCLUSIONS—As the chemistry of glycation would predict, we found no evidence to contradict the simple hypothesis that A1C directly reflects mean glucose over time. There is, however, substantial variability in individual mean glucose concentrations for a given A1C. Transforming reliable A1C values into calculated mean glucose values would, when applied to an individual, introduce substantial error.
Opini AndaKlik untuk menuliskan opini Anda tentang koleksi ini!

Kembali
design
 
Process time: 0 second(s)