Anda belum login :: 26 Nov 2024 19:13 WIB
Home
|
Logon
Hidden
»
Administration
»
Collection Detail
Detail
New point of care Chlamydia Rapid Test—bridging the gap between diagnosis and treatment: performance evaluation study
Oleh:
Mahilum-Tapay, Lourdes
;
Laitila, Vivian
;
Wawrzyniak, James J.
;
Lee, Helen H.
;
Alexander, Sarah
;
Ison, Catherine
;
Swain, Alison
;
Barber, Penelope
;
Ushiro-Lumb, Ines
;
Goh, Beng T.
Jenis:
Article from Journal - ilmiah internasional
Dalam koleksi:
British Medical Journal (keterangan: ada di Proquest) vol. 335 no. 7631 (Dec. 2007)
,
page 1190.
Ketersediaan
Perpustakaan FK
Nomor Panggil:
B16.K.2007.01
Non-tandon:
1 (dapat dipinjam: 0)
Tandon:
tidak ada
Lihat Detail Induk
Isi artikel
Objective To evaluate the performance of a new Chlamydia Rapid Test with vaginal swab specimens as a potential tool for chlamydia diagnosis and screening. Design Performance evaluation study. Settings A young people’s sexual health centre (site 1) and two genitourinary medicine clinics (sites 2 and 3) in the United Kingdom. Participants 1349 women aged between 16 and 54 attending one of the three clinics. Main outcome measures Sensitivity, specificity, positive predictive value, and negative predictive value of the Chlamydia Rapid Test versus polymerase chain reaction and strand displacement amplification assays; correlation between the Chlamydia Rapid Test visual signal and organism load; acceptability to participants of self collected vaginal swabs as the specimen type for Chlamydia testing. Results Polymerase chain reaction positivity rates for Chlamydia trachomatis infection were 8.4% (56/663) at site 1, 9.4% (36/385) at site 2, and 6.0% (18/301) at site 3. Compared with polymerase chain reaction assay, the resolved sensitivity, specificity, positive predictive value, and negative predictive value of the Chlamydia Rapid Test were 83.5% (91/109), 98.9% (1224/1238), 86.7% (91/105), and 98.6% (1224/1242). Compared with strand displacement amplification assay, sensitivity and specificity of the Chlamydia Rapid Test were 81.6% (40/49) and 98.3% (578/588). Organism load of self collected vaginal swabs ranged from 5.97x102 to 1.09x109 Chlamydia plasmids per swab, which correlated well with the Chlamydia Rapid Test’s visual signal (r=0.6435, P<0.0001). Most (95.9%) surveyed participants felt comfortable about collecting their own swabs. Conclusions The performance of the Chlamydia Rapid Test with self collected vaginal swabs indicates that it would be an effective same day diagnostic and screening tool for Chlamydia infection in women. The availability of Chlamydia Rapid Test results within 30 minutes allows for immediate treatment and contact tracing, potentially reducing the risks of persistent infection and onward transmission. It could also provide a simple and reliable alternative to nucleic acid amplification tests in chlamydia screening programmes.
Opini Anda
Klik untuk menuliskan opini Anda tentang koleksi ini!
Kembali
Process time: 0.015625 second(s)